YeeFixx copper sensor / room sensor air-conditioner temperature detector aircond repair part coil sensor suhu tembaga
Price: RM1.70 to RM3.30
Price varies by variant. Select the option you need when you enquire.
- 100% new, ready stock
- Packed within 24 hours
- Malaysia supplier
- Wholesale prices
Available variants 14
Variant: types
- pana 2in1 set
- by pass sensor
- copper sensor 5k ohm
- copper sensor10k ohm
- copper sensor15k ohm
- copper sensor20k ohm
- copper sensor25k ohm
- copper sensor50k ohm
- room sensor 5k ohm
- room sensor 10k ohm
- room sensor 15k ohm
- room sensor 20k ohm
- room sensor 25k ohm
- room sensor 50k ohm
- Weight
- 0.01 kg
- Packing dimension
- 1 cm (Length) x 2 cm (Width) x 1 cm (Height)
- Category
- Aircond Spare Parts
- Stock
- Ready stock
Product description
Description provided by YeeFixx in English and Bahasa Melayu.
English
- for aircond use only
- ohm can using meter checking before buying
- copper sensor is using for detect temperature of copper tubes and If it exceeds the cold temperature set by your remote control, it will cut off the power to the aircond outdoor unit to stop operation, and when the copper pipe is not so cold, it will turn on the power to the outdoor unit again
- room sensor is using for detect temperature of your room and If it exceeds the cold temperature set by your remote control, it will cut off the power to the aircond outdoor unit to stop operation, and when the room is not so cold, it will turn on the power to the outdoor unit again
- if copper sensor / room sensor is got problem , always ohm will drop to zero or will very low ohm , then can replace it
- if your aircond outdoor unit is always cut off when open aircond 2-10min or aircond outdoor always stop and make aircond sometimes cold , sometimes no cold , maybe can check sensor
- nice quality and standard size
- if really socket no suitable , then need modify , just cut wire and use black tape connect it , then can using back old socket
- important things is ohm of copper sensor is don't be too far away
- sensor 4pin dan 2in1 can use in pana.
- 10k copper sensor or room sensor - can use in dkn / acsn / yrk aircond.
Bahasa Melayu
- untuk kegunaan aircond sahaja
- ohm boleh guna meter semak sebelum beli
- Penderia tembaga digunakan untuk mengesan suhu tiub tembaga dan Jika ia melebihi suhu sejuk yang ditetapkan oleh alat kawalan jauh anda, ia akan memotong kuasa unit luar penghawa dingin untuk menghentikan operasi, dan apabila paip tembaga tidak begitu sejuk, ia akan menghidupkan kuasa ke unit luar semula
- sensor bilik digunakan untuk mengesan suhu bilik anda dan , ia akan kontrol elektrik kuasa pergi unit luar aircond operasi semasa panas , dan berhenti semasa sejuk
- jika sensor tembaga / sensor bilik ada masalah , sentiasa ohm akan turun sampai 000 atau akan ohm sangat rendah , kemudian boleh menggantikannya
- jika unit outdoor aircond anda selalu terputus semasa buka aircond 2-10min atau aircond outdoor selalu berhenti dan menyebab aircond kadang sejuk kadang tak sejuk mungkin boleh check sensor
- kualiti bagus dan saiz standard
- Jika benar soket tidak sesuai, maka perlu ubah suai, hanya potong wayar dan gunakan pita hitam sambungkannya, kemudian boleh menggunakan soket belakang lama
- perkara penting ialah ohm sensor tembaga adalah jangan terlalu jauh , ohm tak lari terlalu banyak , biasa tiada masalah
- sensor 4pin dan 2in1 can use in pana.
- 10k copper sensor or room sensor - can use in dkn / acsn / yrk aircond.